mirror of
https://github.com/odoo/documentation.git
synced 2025-12-12 07:29:27 +07:00
169 lines
7.3 KiB
ReStructuredText
169 lines
7.3 KiB
ReStructuredText
:hide-page-toc:
|
|
|
|
===============
|
|
Troubleshooting
|
|
===============
|
|
|
|
The pairing code does not appear or does not work
|
|
=================================================
|
|
|
|
The :ref:`pairing code <iot/connect/pairing-code>` might not be displayed or printed under the
|
|
following circumstances:
|
|
|
|
- The IoT system is not connected to the network.
|
|
- The IoT system is already connected to an Odoo database. :ref:`Disconnect it from the database
|
|
<iot/connect/disconnect>`.
|
|
- The :ref:`pairing code <iot/connect/pairing-code>` display time has expired. Restart the :ref:`IoT
|
|
box <iot/iot-box/restart>` or the :ref:`Windows virtual IoT service <iot/windows_iot/restart>` to
|
|
generate and display the pairing code.
|
|
|
|
The IoT system does not connect to the database
|
|
===============================================
|
|
|
|
The IoT system might take a few minutes to restart when it connects to a database. If it still does
|
|
not appear after a few minutes:
|
|
|
|
- Verify that the IoT system can reach the database and the server does not use a multi-database
|
|
environment.
|
|
- Restart the :ref:`IoT box <iot/iot-box/restart>` or the :ref:`Windows virtual IoT service
|
|
<iot/windows_iot/restart>`.
|
|
|
|
The IoT system is connected to the Odoo database but cannot be reached
|
|
======================================================================
|
|
|
|
Verify that the IoT system and the computer running the Odoo database are connected to the same
|
|
network.
|
|
|
|
The Windows virtual IoT's homepage cannot be accessed from another device
|
|
=========================================================================
|
|
|
|
- Ensure the device is connected to the same network as the Windows virtual IoT.
|
|
- Check the :ref:`iot/windows-iot/firewall`.
|
|
|
|
The IoT system does not work after an Odoo upgrade
|
|
==================================================
|
|
|
|
Restart the :ref:`IoT box <iot/iot-box/restart>` or the :ref:`Windows virtual IoT service
|
|
<iot/windows_iot/restart>`.
|
|
|
|
If the issue persists, :ref:`update its image <iot/updating_iot/image-code>` by flashing the IoT
|
|
box's card or :ref:`uninstalling the Windows virtual IoT program <iot/windows_iot/uninstall>` and
|
|
:ref:`reinstalling the virtual IoT package <iot/windows-iot/installation>`.
|
|
|
|
The IoT system's homepage can be accessed using its IP address but not the `xxx.odoo-iot.com` URL
|
|
=================================================================================================
|
|
|
|
Contact your system or network administrator to address the issue. Network-related problems are
|
|
beyond the scope of Odoo support services.
|
|
|
|
- If the router allows manual :abbr:`DNS (Domain Name System)` configuration, update the settings to
|
|
use `Google DNS <https://developers.google.com/speed/public-dns>`_.
|
|
- If the router does not support this, you need to update the DNS settings directly on each device
|
|
that interacts with the IoT system to use `Google DNS
|
|
<https://developers.google.com/speed/public-dns>`_. Instructions for configuring DNS on individual
|
|
devices can be found on the respective manufacturer's website.
|
|
|
|
.. note::
|
|
- Some IoT devices, such as payment terminals, likely do not require DNS changes, as they are
|
|
typically pre-configured with custom DNS settings.
|
|
- On some browsers, an error code mentioning the DNS (such as `DNS_PROBE_FINISHED_NXDOMAIN`) is
|
|
displayed.
|
|
|
|
.. _iot/troubleshooting/https_certificate:
|
|
|
|
HTTPS certificate generation issues and errors
|
|
==============================================
|
|
|
|
The HTTPS certificate does not generate
|
|
---------------------------------------
|
|
|
|
Potential causes include the following:
|
|
|
|
- The database doesn't meet the :ref:`eligibility requirements
|
|
<iot/https_certificate_iot/iot-eligibility>` for generating an HTTPS certificate.
|
|
- The firewall is preventing the HTTPS certificate from generating correctly. In this case,
|
|
deactivate the firewall until the certificate is successfully generated.
|
|
|
|
.. note::
|
|
Some devices, such as routers with a built-in firewall, can prevent the HTTPS certificate from
|
|
generating.
|
|
|
|
Errors
|
|
------
|
|
|
|
A specific error code is displayed on the IoT system's homepage if any issues occur during the
|
|
generation or reception of the HTTPS certificate.
|
|
|
|
.. tip::
|
|
When you access the IoT system's homepage, it automatically checks for an HTTPS certificate and
|
|
attempts to generate one if it is missing. If an error appears, refresh the page to see if the
|
|
issue is resolved.
|
|
|
|
`ERR_IOT_HTTPS_CHECK_NO_SERVER`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The server configuration is missing, i.e., the database is not :doc:`connected <../connect>` to
|
|
the IoT system.
|
|
|
|
`ERR_IOT_HTTPS_CHECK_CERT_READ_EXCEPTION`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
An error occurred while attempting to read the existing HTTPS certificate.
|
|
Verify that the HTTPS certificate file is readable.
|
|
|
|
`ERR_IOT_HTTPS_LOAD_NO_CREDENTIAL`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The contract and/or database :abbr:`UUID (Universal Unique Identifier)` is missing from the IoT.
|
|
|
|
Verify that both values are correctly configured. To update them, :ref:`access the IoT box's
|
|
<iot/iot-box/homepage>` or :ref:`Windows virtual IoT's homepage <iot/windows-iot/homepage>`,
|
|
click the :icon:`fa-cogs` (:guilabel:`cogs`) button, then click :guilabel:`Credentials`.
|
|
|
|
`ERR_IOT_HTTPS_LOAD_REQUEST_EXCEPTION`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
An unexpected error occurred while the IoT system tried to reach `<https://www.odoo.com>`_. This is
|
|
likely due to network-related issues, such as:
|
|
|
|
- The IoT system does not have Internet access.
|
|
- Network restrictions (e.g., firewalls or VPNs) are preventing communication with
|
|
https://www.odoo.com.
|
|
|
|
.. note::
|
|
- To access the full request exception details with information regarding the error, :ref:`enable
|
|
the developer mode <developer-mode>`, click the IoT system's card in the IoT app, and click
|
|
:guilabel:`Download logs` on the :ref:`IoT system's form <iot/connect/IoT-form>`.
|
|
To define the log levels recorded in the IoT system's log file, :ref:`access the IoT box's
|
|
<iot/windows-iot/homepage>` or :ref:`Windows virtual IoT's <iot/iot-box/homepage>` homepage,
|
|
click the :icon:`fa-cogs` (:guilabel:`cogs`) button, then :guilabel:`Log level` at the
|
|
bottom of the page.
|
|
- To address network-related issues, contact your system or network administrator; these issues
|
|
are beyond the scope of Odoo support services.
|
|
|
|
`ERR_IOT_HTTPS_LOAD_REQUEST_STATUS`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The IoT system successfully reached `<https://www.odoo.com>`_ but received an unexpected
|
|
`HTTP response (status codes) <https://developer.mozilla.org/en-US/docs/Web/HTTP/Status>`_.
|
|
|
|
This error code includes the HTTP status. For example, `ERR_IOT_HTTPS_LOAD_REQUEST_STATUS 404` means
|
|
the server returned a "Page Not Found" response.
|
|
|
|
To solve this issue:
|
|
|
|
#. Open `<https://www.odoo.com>`_ in a web browser to check if the website is temporarily down for
|
|
maintenance.
|
|
#. | If `<https://www.odoo.com>`_ is down for maintenance, wait for it to resume.
|
|
| If the website is operational, open a `support ticket <https://www.odoo.com/help>`_ and make
|
|
sure to include the 3-digit HTTPS status code in the ticket.
|
|
|
|
`ERR_IOT_HTTPS_LOAD_REQUEST_NO_RESULT`
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The IoT system successfully connected to `<https://www.odoo.com>`_, but the server refused to
|
|
provide the HTTPS certificate.
|
|
|
|
Check that the IoT system and database meet the :ref:`eligibility requirements
|
|